InertSustain C18 HPLC Column, 2 µm, 150 x 2.1 mm

SKU: 5020-14355
$880.00
+ -

Specifications

InertSustain C18 HPLC Column, 2 µm, 150 x 2.1 mm SKU: 5020-14355

Specifications
Attribute nameAttribute value
Column or GuardColumn
Column formatAnalytical
PhaseInertSustain C18
Base MaterialHigh Purity ES Silica Gel
Functional groupOctadecyl
Particle size2 µm
Length150 mm
Inner diameter2.1 mm
ModeReversed phase
Surface area350 m2/g
Pore size100 Å (10 nm)
Pore volume0.85 mL/g
End cappingYes
Carbon loading14.0%
pH Range1-10
Unit size1 pc.
Max Operating Pressure80 MPa(800 bar)
USP CodeL1

InertSustain C18 HPLC Columns - Overview

Tailing of peaks or adsorption of peaks can be experienced when a column has residual adsorption sites. Such phenomenon would not be observed on InertSustain as the silanols are completely end-capped, having a neutral silica surface. 

Figure 1 : Basic Compounds

InertSustain C18 Figure 1: Basic Compounds

Figure 2 : Acidic Compounds

InertSustain C18 Figure 2: Acidic Compounds

Figure 3 : Chelating Compounds

InertSustain C18 Figure 3: Chelating Compounds

Comparison of Performance to Core-Shell Columns

As shown below, core-shell columns show peak tailing due to the presence of trace metals or silanol groups in their silica gel. Quantitative and qualitative analysis will be a source of concern since the adsorption of compounds can be expected.

InertSustain C18 HPLC Columns Comparison to Core-shell columns

Wide pH compatibility with Long Column Lifetime

As shown in the experiment below, due to the introduction of Evolved Surface Silica, InertSustain C18 columns maintained high efficiency and peak shape for 300 hours while other “wide pH” column brands failed.

InertSustain C18 HPLC Columns Column Lifetime graph

Experience the InertSustain! (Inertness and Sustainability)

Highly end-capped ODS columns such as InertSustain C18 columns offer an opportunity to flush out contaminants from the column surface easily using an organic solvent. Coffee melanoidins are brown heterogeneous polymers contained in coffee. Its components are not clarified yet, but it is considered to contain several ionic compounds, which a poorly end-capped column will adsorb those ionic compounds leading to short column lifetime.

As for ODS column, which is commonly used for HPLC and LC/MS/MS, its inertness has an influence not only on peak shape but also detection sensitivity and durability. It is highly recommended to use highly end-capped column which provides good peak shape for both basic and acidic compounds such as InertSustain C18.

InertSustain C18 HPLC Columns Flushing figure

Reliable Reproducibility, Performance and Quality

Rigorous quality control of physical properties and strict chromatographic tests for inertness and selectivity, contribute to the production of InertSustain C18 columns with outstanding reproducibility and long column lifetime.

Figure 4 : Strong Basic Compound Test

InertSustain C18 Figure 4: Strong Basic Compound Test

Figure 5 : Strong Acidic Compound Test

InertSustain C18 Figure 5: Strong Acidic Compound Test

Figure 6 : Strong Chelating Compound Test

InertSustain C18 Figure 6: Strong Chelating Compound Test