English
You have no items in your shopping cart.

HPLC Columns

GL Sciences columns provide excellent separation and resolution of target compounds featuring new high-purity evolved surface silica. GL Sciences columns silica base is uniquely modified to provide maximum column performance including low operating back-pressure, high inertness, high efficiency and wide solvent compatibility. Get the appropriate column from a large selection of column configurations and formats compatible with many HPLC methods including analytical, preparative, capillary HPLC and UHPLC. Read more

Filters
per page
Inertsil CN-3, Cyanopropryl groups bonded to Silica gel with high density. And it is not only increase difference recognition of hydrophilicity, but also increase the durability. It is difficult to increase the both performance with other previous cyanopropryl columns. Inertsil CN-3 can be cleaned with 100 % aqueous solvent because non-sp...
From $244.00
Inertsil SIL-150A is ultra pure silica gel column, and this ultra pure silica gel contains very low level of metal impurities and is durable and free from dents and cracks which can cause premature column failure. Compared to Inertsil SIL-100A, the silica’s surface area is smaller (320 m²/ g). Retentivity of Inertsil SIL-150A is weaker th...
From $280.00
Inertsil WP300 SIL is pure silica gel phase with wide pores(300 Å). It is available for analysing compounds including large molecules. As the pore becomes wider, the surface area of silica gel is smaller. Since the interactions between the analyte and silica gel occur on the sIlica surface, smaller surface area means less interactions and...
From $244.00
Inertsil WP300 Diol has dihydroxypropyl group bonded to silica gel with pore size 300 Å and is capable of analyzing large molecules. Like Inertsil Diol, Inertsil WP300 Diol can be used for both aqueous SEC (Size Exclusion Chromatography) and organic SEC. Also, as a diol column, Inertsil WP300 Diol can be used in both normal phase and reve...
From $244.00
Inertsil AX has diethylamino groups bonded to silica gel by an alkyl chain. The diethylamino groups offer anionic functions required for anion exchange chromatography. It is mainly used for analyses of acidic compounds. Conventional ion-exchange columns used to show inconsistent results from lot to lot. However, Inertsil AX is manufacture...
From $244.00
The Inertsil CX Cation Exchange HPLC Column has benzenesulfonyl groups bonded to silica gel by an alkyl chain. The sulfonyl groups at the end of the structure offer cationic functions required for the cation exchange chromatography. It is mainly used for analyses of basic compounds. Inertsil CX is manufactured under strict quality control...
From $244.00
From $210.00
Specifications • Base Material : 3 Series High Purity Silica Gel • Particle Size : 3 μm, 5 μm • Surface Area : 450 m²/g • Pore Size : 100 Å (10 nm) • Pore Volume : 1.05 mL/g • Functional Group : Octadecyl • End-capping : Yes • Carbon Loading : 15 % • USP Code : L1
From $310.00
From $168.00
Amide groups are chemically bonded to the monolithic silica and makes it suitable for the analysis of sugars via HILIC mode. As the back pressure is significantly low, a 500 mm length MonoCap Amide column deliver over 40,000 plates offering high efficiency. Generally, HILIC mode uses acetonitrile at a concentration between 65-95 % in an a...
Workable at a broad range of linear velocity from 0.5 to 5 mm/s without sacrificing efficiency and separation at high speed. The number of theoretical plates produced by MonoCap C18 Fast-flow is nearly equivalent to a totally porous particle type capillary column packed with a 5µm packing material. Columns are protected by either metal or...
From $1,140.00
Maximizing all the benefits and advantages of monolithic technology, MonoCap High Resolution and High Resolution Ultra are appropriate for the efficient separation of peptides and protein digests. MonoCap High Resolution provide extremely high efficiency, delivering over 200,000 plates for a 2,000 mm length column. The High Resolution...
From $5,090.00
MonoCap C18 Nano-flow produces higher number of theoretical plates compared to a totally porous particle type capillary column packed with a 3µm packing material. It can be operated at a wide range of flow rate with low back pressure and achieve very high sensitive results in Nano-LC-ESI/MS applications. Columns are protected by either me...
From $1,200.00
MonoCap Trap columns have a relatively big throughpore and workable at a high flow rate such as 10 μL/min. This benefit makes MonoCap Trap columns to be appropriate for on-line preconcentration or desalting of protein and peptide samples prior to HPLC separation with mass spectrometry detection. End-fittings are 1/16“ (10-32 UNF). 1/32“...
From $260.00
The MonoCap C18 Fast-flow is also available in 0.5 mm I.D. size, which can be used at a wide range of flow rate from 6 to 100 L/min without sacrificing efficiency. The number of theoretical plates produced by MonoCap C18 WideBore is nearly equivalent to a totally porous particle type capillary column packed with a 5µm packing material. Co...
MonoCap SCX is bonded with benzene sulfonic acid groups (strong cation exchange) and appropriate for 2D LC applications for the separation of biomolecules such as peptides and proteins.
MonoSelect C18 for HTS is based on monolithic silica technology. The very low flow resistance and the excellent separation performances make it suitable for High-Throughput Screenings (HTS). Due to its metal-free hardware, sharp peaks can be obtained also when analyzing metal chelators. The particular structure of MonoSelect C18 for HTS p...
From $270.00
MonoSelect nPEC uses nanoparticle exclusion chromatography (nPEC). It can rapidly separate nano-particles and free-low molecule compounds. Specifications • Silica:High Purity Monolithic Silica Gel • Through Pore Size: 1 µm • Surface Area: 340 m2/g • Pore Size (Moso-pore Size): 110 Å (11 nm) • Functional Group: Hydrophilic Pol...
From $1,200.00
MonoSelect RP-mAb is an HPLC column specialized for monoclonal antibody analysis. Monolithic silica delivers “Strong Retentivity and Low Adsorption”. Sharp peaks can perform even in large molecular protein analysis such like antibodies. Specifications • Base Material: Highly Pure Monolithic Silica • Through Pore Size: 1 µm • Mos...
From $278.00
SKU# 5020-90005
Delay Column for PFAS is packed with high-purity activated carbon, which is able to retain contaminants originating from the mobile phase or the LC system. Elution of retained contaminants is delayed allowing for the effects of the contaminants on the analysis to be reduced. This column is quite useful for PFAS (Per- and Polyfluoroalkyl S...
$660.00
SKU# 5020-08550
$220.00
SKU# 5020-06920
Guard
$330.00
SKU# 5020-08500
$220.00
SKU# 5020-08630
$330.00
SKU# 5020-08650
$290.00
SKU# 5020-08710
GL Econo Cartridge Holder
$220.00
SKU# 5020-10044
$260.00
SKU# 5020-10045
$230.00
SKU# 5020-10046
$98.00
SKU# 5020-10047
$78.00
SKU# 5020-10017
$105.00
SKU# 5020-05953
Call for pricing
SKU# 5020-85832
$1,210.00
SKU# 5020-85834
$1,600.00
SKU# 5020-85835
$1,800.00
SKU# 5020-85836
$2,270.00
SKU# 5020-79071
$1,580.00
SKU# 5020-79072
$2,680.00
SKU# 5020-79073
$3,220.00
SKU# 5020-79074
$3,140.00
SKU# 5020-85842
$1,800.00

HPLC Column Types​

GL Sciences offers different column types to support all major separation modes used in HPLC:

Non-polar phases including alkyl phases such as C18, C8, C4 and other functionalities such as phenyl and cyano groups. GL Sciences provides a diverse range of reverse phases for different analyte retentivities and selectivities by group modification. A high degree of analyte targeting can be achieved using our selection of reverse phases.

ColumnFeaturesUSP CodeMicron (µm)Pore Size (nm)Surface Area (m2/g)
InertSustain C18First choice with ultra high inertness and high durabilityL12, 3, 5, 1010350
InertSustain AQ-C18First choice for high polar compoundsL1, L961.9, 3, 510350
InertSustainSwift C18First analysis with ultra high inertness and high durabilityL11.9, 3, 520200
InertSustain AX-C18Analysis of anionic highly polar compoundsL1, L783, 520200
InertCore Plus C18Ideal for analyses requiring a high number of theoretical stagesL12.69200
Inertsil ODS-HLUltra high retentivity, High-density bonding of C18 phaseL13, 510450
Inertsil ODS-4Ultra high inertness, High plate count, Medium retentivityL12, 3, 510450
Inertsil ODS-4VInertsil ODS-4 Validated columnL13, 510450
Inertsil ODS-3Strong retentivity, Lower column backpressure, Very inertL12, 3, 4, 5, 1010450
Inertsil ODS-3VInertsil ODS-3 Validated columnL13, 510450
Inertsil ODS-SPWeak retentivity, for hydrophobic compoundsL13, 510450
Inertsil ODS-PHigh steric selectivityL13, 510450
Inertsil ODS-EPA polar functional group embeddedL1510450
Inertsil WP300 C18Analysis of high moleculesL1530150
Inertsil ODS-2Ultra pure silica gel is usedL1515320
Inertsil ODSInertness 1st generationL15, 1010350
InertSustain C8First choice with ultra high inertness and high durabilityL72, 3, 510350
InertSustainSwift C8High inertness and high durability C8 columnL71.9, 3, 520200
Inertsil C8-4Ultra high inertness, High plate count, Low retentivityL72, 3, 510450
Inertsil C8-3Strong retentivity, Lower column backpressure, Very inertL72, 3, 5, 1010450
Inertsil C8Ultra pure silica gel is usedL7515320
Inertsil C4Low retentivityL26515320
Inertsil WP300 C8Suitable for high moleculesL7530150
Inertsil WP300 C4Suitable for high moleculesL26530150
InertSustain PFPExtremely Strong retention of highly polar basic compoundsL433, 510350
InertSustain PhenylhexylStrong π-π interactions and hydrophobic interactionsL113, 510350
InertSustain PhenylExtremely strong π-π interactionsL112, 3, 510350
Inertsil Ph-3Strong π-π interactionsL112, 3, 510450
Inertsil PhHigh inertness, Weak π-π interactionsL11515320
InertSustain CyanoUltra inertness and can be used in reversed phase modeL103, 510350
 

Phases providing high retentivity of polar compounds in immobilized water layers on the stationary phase surface in hydrophilic interaction liquid chromatography (HILIC) mode. Our choice of funtionalities allow for an excellent spread of different separation patterns for the analysis of compounds such as sugars.

ColumnFeaturesUSP CodeMicron (µm)Pore Size (nm)Surface Area (m2/g)
InertSustain AmideFirst choice for HILIC modeL683, 510350
Inertsil HILICSeparation of highly polar basic compoundsL203, 510450
InertSustain NH2First choice for sugar analysisL83, 510350
Inertsil NH2Sugar analysis, High retentive in normal phase modeL83, 510450
Inertsil AmideIncreasing retentivity of high polar compoundsL683, 510450
 

Phases with ionizable functional groups having high ion exchange capacities are available for both anion and cation exchange chromatography. We feature popular groups for wide method compatibility. In addition, mix-mode columns featuring alkyl groups are available for alternate selectivity.

ColumnFeaturesUSP CodeMicron (µm)Pore Size (nm)Surface Area (m2/g)
Inertsil AXAnion-exchange column510450
Inertsil CXCation-exchange columnL9510450
InertSustain AX-C18Analysis of anionic highly polar compoundsL1, L783, 520200
 

High performance phases for retentivity of polar compounds. Our normal phases are available a wide range of pore sizes (10-30 nm) for excellent choice in retentivity and selectivity in analysis of up to large molecules.

ColumnFeaturesUSP CodeMicron (µm)Pore Size (nm)Surface Area (m2/g)
Inertsil DiolFirst choice for normal phase mode, For SECL203, 510450
Inertsil SIL-100AUltra pure silica gel with 100Å pore sizeL33, 510450
Inertsil SIL-150AUltra pure silica gel with 150Å pore sizeL3515320
Inertsil WP300 SILUltra pure silica gel with 300Å pore sizeL3530150
Inertsil CN-3Can be also used in reversed phase modeL103, 510450
InertSustain CyanoUltra inertness and can be used in reversed phase modeL103, 510350
 

Columns featuring diol phases in convenient pore sizes that are compatible with aqueous (GFC) or organic (GPC) size-exclusion chromatography. Our columns are available in smaller inner diameters for solvent saving, low-cost analysis. Serial coupling using different GL Sciences SEC columns allows for analysis of a broad range of molecular weights. 

ColumnFeaturesUSP CodeMicron (µm)Pore Size (nm)Surface Area (m2/g)
Inertsil WP300 DiolHigh molecule SEC, Can be also used in normal phase modeL20, L33530150
Inertsil DiolFirst choice for normal phase mode, For SECL203, 510450
 

HPLC Column Selection Guide

 

Separation Mode Selection for Analyte Polarity

Separation Mode Selection for Analyte Polarity
 

Column Selection for Analyte Properties

 

Column Selection for Vitamins

Column selection for vitamins
List of vitamins
 

Column Selection for Sugars and Nucleic acids

Column Selection for Sugars and nucleic acids
 

Column Selection for Medicines

Column Selection for Medicines
 

Column Selection for Organic acids

Column Selection for Organic acids
 

Column Selection for Amino acids

Column Selection for Amino acids
 

Column Selection for Proteins and Peptides

Column selection for Proteins and Peptides
 

Column Selection for Pesticides, Veterinary medicines, Aldehydes and Polymers

Column selection for Pesticides, Veterinary Medicines, Aldehydes and Polymers
 

HPLC Columns Resources:​

  • Download GL Sciences 2022 HPLC Columns Catalog — Download
  • Download GL Sciences 2022 InertSustain Catalog— Latest HPLC Column Technology Download
  • Search Application Notes For HPLC Columns — Search Applications Database
  • HPLC Columns’ Specification — Summary of GL Sciences HPLC Column Specifications. Learn More
  • HPLC Column Selection Overview — Separation mode selection for analyte polarity & HPLC column selection for analyte properties. Learn More
  • HPLC Column Selection By USP — Recommended GL Sciences HPLC Columns based on USP Code. Learn More
  • HPLC Column End Fittings — Summary of GL Sciences' end-fitting style & recommended operating pressure. Learn More
  • Reversed Phase HPLC Column Selection Guide— Download Reverse Phase HPLC Column Selection Guide. Learn More
  • Normal Phase Selection Guide — Download Normal Phase HPLC Column Selection Guide. Learn More
  • How to Select a Guard Column — Download guide to select the right guard column. Learn More
  • Choosing a Preparative Column — Download Guide to select the right preparative column. Learn More
Filters
Refine
;;