GL Sciences’ InertSep SPE products contain sorbents and are created using the same advanced silicas and bonding technologies like those used to create Inertsil HPLC packings. Therefore, InertSep SPE cartridges and 96-well plates show exceptional purity, excellent reproducibility, high recoveries/low non-specific binding, low- to non-existent backgrounds from reagents used to manufacture the column housing, and rigid durability over a wide pH range.
InertSep K-solute is packed with diatomaceous earth and ideal even for the sample to form an emulsion during liquid-liquid extraction procedure. Dedicated rack for InertSep makes the operation simple and efficient.
InertSep mini AERO series are active samplers for the analysis of Aldehydes and Ketones in outdoor gas, car cabin and exhaust gas in compliance with: Offensive Odor Control Law, Clean Air Act, and EPA. There are four types: AERO DNPH, AERO DNPH-HR, AERO Ozone Scrubber, and AERO SC, InertSep mini AERO series.
These two layer cartridges are packed with graphite carbon for removing pigments and PSA sorbent for sample cleanup of organic extracts. This consolidation of two layers achieves high sample cleanup performance which cannot be obtained only on one layer.
InertSep Phospholipid is developed for removal of phospholipids selectively and is able to minimize ion suppression of LC/MS/MS analysis. It can remove more than 90 % of phospholipids.
These two layer cartridges are packed with graphite carbon for removing pigments and NH2 sorbent for sample cleanup of organic extracts. This consolidation of two layers achieves high sample cleanup performance which cannot be obtained only on one layer.
InertSep PCB is a two layer SPE cartridge packed with SCX and SI. It has been designed for the extraction of PCBs from complex matrix. InertSep PCB is generally used for the extraction of isolates from matrices such as oil and milk.
InertSep SAX/PSA is a two layer SPE cartridge packed with SAX and PSA. It is used specifically where the polar interaction is ideal for agrochemical compounds that are often difficult to remove from crop samples.
A large number of mycotoxins are contained in natural food products. Among these, Aspergillus flavus is known to produce aflatoxins that are carcinogenic to liver cells. Mycotoxins in food safety have received a great deal of attention in recent years.
These two-layer cartridges are packed with GC-e graphite carbon for removing pigments and PSA sorbent for sample cleanup of organic extracts. Due to the cost reduction of GC-e, these two-layer cartridges achieve high sample cleanup performance at low cost.
These two-layer cartridges are packed with GC-e graphite carbon for removing pigments and NH2 sorbent for sample cleanup of organic extracts. Due to the cost reduction of GC-e, these two-layer cartridges achieve high sample cleanup performance at low cost.
InertSep HLB is a solid-phase extraction column that can effectively extract compounds with a wide range of physical properties from non-polar to high polar.
InertSep RP-1 is a copolymer based sorbent comprised of methacrylate and SDB, it exhibits a wide enough range of retention capability from low-polar to hydrophobic compounds. It is also suit for clean up.
InertSep Pharma is a copolymer based sorbent comprised of nitrogen-containing methacrylate and SDB. This sorbent was developed for simultaneous screening of drug metabolites in biological sample.
InertSep PLS-3 is a copolymer based sorbent comprised of nitrogen-containing methacrylate and SDB, it exhibits a wide enough range of retention capability from highly polar to hydrophobic compounds.
InertSep RP-2 is a SDB polymer based sorbent modified with weak anion exchange and hydrogen bonding functional groups. This sorbent is suit for concentration of low-retentive polar compounds with RP-1 and simultaneous screening under polar interactions.
InertSep MPC is a SDB polymer based sorbent modified with strong cation exchange and C18 functional groups. Because of its hydrophobic and ion-exchange properties, it is useful for pretreatment of basic compounds from hydrophobic compounds in blood and urine for simultaneous analysis of metabolites. It can also be used for separation and...
InertSep Pharma FF is an arranged version of InertSep Pharma for applications that need high flow rate and good at viscous biological sample and large volume sample.
InertSep MA-1 is a methacrylate polymer based sorbent modified with strong anion exchange functional groups. The primary advantages of this sorbent are high hydrophilicity and attainability of easy and effective elution of isolates.
InertSep ME-2 is a chelating resin sorbent, developed for SPE of trace metal ions in seawater. As this sorbent does not retain Ca and Mg ions, desalting can be achieved by passing the sample through the sorbent and wash with purified water.
InertSep MC-2 is a methacrylate polymer based sorbent modified with week cation exchange functional groups. This sorbent is suitable for SPE of strong anion compounds in ion exchange mode. Because polymer base gel occurs little secondary interaction, SPE by genuine cation exchange interaction can be achieved with this sorbent.
InertSep ME-1 is a methacrylate copolymer based solid sorbent modified with iminodiacetic acid, weak cation exchange functional groups. It is highly hydrophilic and does not retain monovalent Na ion or K ion, but it does retain metal divalent or more cations. This offers selective concentration of such metal ions and is suitable for custo...
InertSep MAX FF is a sorbent based on styrene divinylbenzene polymer modified by a strong anion-exchange group. Its reversed-phase, anion-exchange action and exceptional retention of acidic compounds make it suitable for recovery from samples containing basic and neutral impurities.
InertSep MC-1 is a methacrylate polymer based sorbent modified with strong cation exchange functional groups. The primary advantages of this sorbent are high hydrophilicity and attainability of easy and effective isolation of cationic compounds.
InertSep SCX-2 employs the same chemical modification with InertSep SCX. The only difference is that benzene sulfonyl propyl functional groups are bonded more densely on the silica surface to increase ion exchange capacity and retentivity.
InertSep WCX FF is a sorbent based on styrene divinylbenzene polymer modified by a weak cation-exchange group. Its reversed-phase, cation-exchange action make it ideal for pretreatment of basic compounds such as MCX. By controlling the pH, it can be used to recover strongly basic compounds under acidic conditions.
InertSep GC cartridges are packed with graphite carbon in planar structure. They are generally used for removal of pigments from crop homogenates. In conjunction with other various normal phase sorbents and ion exchange sorbents, these cartridges are able to be used for a wide variety of applications as a cleanup sorbent.
InertSep MCX FF is a sorbent based on styrene divinylbenzene polymer modified by a strong cation-exchange group. Its reversed-phase, cation-exchange action and exceptional retention of basic compounds make it suitable for recovery from samples containing acidic and neutral impurities.
InertSep GC-e cartridges are packed with graphite carbon which has similar physical properties to InertSep GC. InerSep GC-e provides the same extraction performance as InertSep GC at low cost.